#4502 fixed BSoD before windows logon if VT-x/AMD-V is disabled antonio
Description

Host: Opensuse 11.0 kernel 2.6.25.20-0.4-pae Guest: Windows XP sp3

Occurs only if VT-x/AMD-V is disabled and cause infinite loop (reboot).

#11730 obsolete BSoD in VBoxNetAdp.sys with STOP 0x9F bigjohn
Description

started to happen after I updated to 4.2.12 recently.

WinDbg shows this:

0: kd> !analyze -v
*******************************************************************************
*                                                                             *
*                        Bugcheck Analysis                                    *
*                                                                             *
*******************************************************************************

DRIVER_POWER_STATE_FAILURE (9f)
A driver is causing an inconsistent power state.
Arguments:
Arg1: 0000000000000003, A device object has been blocking an Irp for too long a time
Arg2: fffffa800c779700, Physical Device Object of the stack
Arg3: fffff80000b9c3d8, Functional Device Object of the stack
Arg4: fffffa802db99e10, The blocked IRP

Debugging Details:
------------------


DRVPOWERSTATE_SUBCODE:  3

IRP_ADDRESS:  fffffa802db99e10

DEVICE_OBJECT: fffffa800fece050

DRIVER_OBJECT: fffffa800ff91c50

IMAGE_NAME:  VBoxNetAdp.sys

DEBUG_FLR_IMAGE_TIMESTAMP:  5167d67e

MODULE_NAME: VBoxNetAdp

FAULTING_MODULE: fffff88003083000 VBoxNetAdp

DEFAULT_BUCKET_ID:  VISTA_DRIVER_FAULT

BUGCHECK_STR:  0x9F

PROCESS_NAME:  System

CURRENT_IRQL:  2

LAST_CONTROL_TRANSFER:  from fffff80003b008c2 to fffff80003a90c00

STACK_TEXT:  
fffff800`00b9c388 fffff800`03b008c2 : 00000000`0000009f 00000000`00000003 fffffa80`0c779700 fffff800`00b9c3d8 : nt!KeBugCheckEx
fffff800`00b9c390 fffff800`03a9b84c : fffff800`00b9c4c0 fffff800`00b9c4c0 00000000`00000000 00000000`00000001 : nt! ?? ::FNODOBFM::`string'+0x33af0
fffff800`00b9c430 fffff800`03a9b6e6 : fffff800`03c40f20 00000000`0102ee6a 00000000`00000000 00000000`00000000 : nt!KiProcessTimerDpcTable+0x6c
fffff800`00b9c4a0 fffff800`03a9b5ce : 00000268`5b46c05a fffff800`00b9cb18 00000000`0102ee6a fffff800`03c0efc8 : nt!KiProcessExpiredTimerList+0xc6
fffff800`00b9caf0 fffff800`03a9b3b7 : 0000009c`23d535c1 0000009c`0102ee6a 0000009c`23d535a4 00000000`0000006a : nt!KiTimerExpiration+0x1be
fffff800`00b9cb90 fffff800`03a8890a : fffff800`03c0be80 fffff800`03c19cc0 00000000`00000002 fffff880`00000000 : nt!KiRetireDpcList+0x277
fffff800`00b9cc40 00000000`00000000 : fffff800`00b9d000 fffff800`00b97000 fffff800`00b9cc00 00000000`00000000 : nt!KiIdleLoop+0x5a


STACK_COMMAND:  kb

FOLLOWUP_NAME:  MachineOwner

FAILURE_BUCKET_ID:  X64_0x9F_IMAGE_VBoxNetAdp.sys

BUCKET_ID:  X64_0x9F_IMAGE_VBoxNetAdp.sys

Followup: MachineOwner
---------

0: kd> lmvm VBoxNetAdp
start             end                 module name
fffff880`03083000 fffff880`030aa000   VBoxNetAdp   (no symbols)           
    Loaded symbol image file: VBoxNetAdp.sys
    Image path: \SystemRoot\system32\DRIVERS\VBoxNetAdp.sys
    Image name: VBoxNetAdp.sys
    Timestamp:        Fri Apr 12 05:40:14 2013 (5167D67E)
    CheckSum:         0002AC27
    ImageSize:        00027000
    Translations:     0000.04b0 0000.04e4 0409.04b0 0409.04e4
#14542 fixed BSoD on W7 host with Linux guest on VB 5.02 ellell
Description

Hi Guys,

since I have upgraded VirtualBox to v5.02, it causes a BSoD when ever my Linux guest system is coming up.

VirtualBox: v5.02 r10.20.96 Host: Windows 7, Release: 6.1.7601, Service Pack: 1, 64bit Host RAM: 7872MB total, 3806MB available Guest: 'Linux26_64'

Here are the information I have found in the dump file of my W7:

090115-12792-01.dmp 01.09.2015 13:51:03 SYSTEM_SERVICE_EXCEPTION 0x0000003b 00000000`c0000005 fffff880`032d13db fffff880`0e2dba40 00000000`00000000 VBoxNetLwf.sys VBoxNetLwf.sys+33db x64 ntoskrnl.exe+735c0

Out of curiosity I have deinstalled v5.02 and installed and tested with VB 4.3.30 -> no BSoD anymore (just the mouse seems to be "disturbed").

Pleae find the logfile attached.

Do you need anything else?

Thanks,